Write a short, relevant description of the device. Include a technical overview, but avoid marketing buzzwords/useless stuff. Two to four sentences is about right. A picture is good, too. Edit the page to see how to add pictures.
Any text with a light background (like this one) provides instructions for creating the Details Page. When you have filled in correct/useful information (instead of any template that's there) remove the instructions, as well as the
<WRAP> that encloses it.
<WRAP> that encloses it.
None at this time.
As of now only snapshot are available for RE205 V3 devices. Please read snapshot before installing.
Find out flash layout, then add the flash layout table here (copy, paste, modify the example).
Please check out the article Flash layout. It contains examples and explanations that describe how to document the flash layout.
http://192.168.1.1 if LuCI is installed.
Enter values for “FILL-IN” below
| Bootloader tftp server IPv4 address | FILL-IN |
|---|---|
| Bootloader MAC address (special) | FILL-IN |
| Firmware tftp image | Latest OpenWrt release (NOTE: Name must contain “tftp”) |
| TFTP transfer window | FILL-IN seconds |
| TFTP window start | approximately FILL-IN seconds after power on |
| TFTP client required IP address | FILL-IN |
→ Basic configuration After flashing, proceed with this.
→ hardware.button on howto use and configure the hardware button(s). Here, we merely name the buttons, so we can use them in the above Howto.
Please fill in real values for this device, then remove the EXAMPLEs
The TP-Link RE205 has the following buttons:
| BUTTON | Event |
|---|---|
| EXAMPLE Reset | reset |
| EXAMPLE Secure Easy Setup | ses |
| EXAMPLE No buttons at all. | - |
Front:
Insert photo of front of the casing
Back:
Insert photo of back of the casing
Backside label:
Insert photo of backside label
→ Warranty
Describe what needs to be done to open the device, e.g. remove rubber feet, adhesive labels, screws, ...
Main PCB:
Insert photo of PCB
→ port.serial general information about the serial port, serial port cable, etc.
How to connect to the Serial Port of this specific device:
Insert photo of PCB with markings for serial port
Replace EXAMPLE by real values.
| Serial connection parameters for TP-Link RE205 @@Version@@ | EXAMPLE 115200, 8N1, 3.3V |
|---|
→ port.jtag general information about the JTAG port, JTAG cable, etc.
How to connect to the JTAG Port of this specific device:
Insert photo of PCB with markings for JTAG port
None so far.
U-Boot 1.1.3 (Aug 24 2022 - 10:39:45)
Board: Ralink APSoC DRAM: 64 MB
relocate_code Pointer at: 83fb8000
flash manufacture id: 20, device id 70 17
find flash: W25Q64BV
*** Warning - bad CRC, using default environment
============================================
Ralink UBoot Version: 4.1.0.0
--------------------------------------------
ASIC 7628_MP (Port5<->None)
DRAM component: 512 Mbits DDR, width 16
DRAM bus: 16 bit
Total memory: 64 MBytes
Flash component: SPI Flash
Date:Aug 24 2022 Time:10:39:45
============================================
icache: sets:512, ways:4, linesz:32 ,total:65536
dcache: sets:256, ways:4, linesz:32 ,total:32768
##### The CPU freq = 580 MHZ ####
estimate memory size =64 Mbytes
RESET MT7628 PHY!!!!!!
Please choose the operation:
1: Load system code to SDRAM via TFTP.
2: Load system code then write to Flash via TFTP.
3: Boot system code via Flash (default).
4: Entr boot command line interface.
7: Load Boot Loader code then write to Flash via Serial.
9: Load Boot Loader code then write to Flash via TFTP.
default: 3
You choosed 1
1: System Load system code to SDRAM via TFTP
Please Input new ones /or Ctrl-C to discard
Input device IP (192.168.0.254) ==:192.168.0.254
Input server IP (192.168.0.184) ==:192.168.0.184
Input Linux Kernel filename () ==:test.bin
NetTxPacket = 0x83FE7840
KSEG1ADDR(NetTxPacket) = 0xA3FE7840
NetLoop,call eth_halt !
NetLoop,call eth_init !
Trying Eth0 (10/100-M)
Waitting for RX_DMA_BUSY status Start... done
ETH_STATE_ACTIVE!!
TFTP from server 192.168.0.184; our IP address is 192.168.0.254
Filename 'test.bin'.
TIMEOUT_COUNT=10,Load address: 0x82000000
Loading: Got ARP REPLY, set server/gtwy eth addr (ac:22:2b:cb:56:e5)
Got it
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#################################################################
#####################################
done
Bytes transferred = 6509106 (635232 hex)
LoadAddr=82000000 NetBootFileXferSize= 00635232
**Erasing SPI Flash...**
**.**
**Writing to SPI Flash...**
done
Automatic boot of image at addr 0x82000000 ...
## Booting image at 82000000 ...
text base: 80000000
entry point: 80000000
Uncompressing Kernel Image ... OK
No initrd
## Transferring control to Linux (at address 80000000) ...
## Giving linux memsize in MB, 64
Starting kernel ...
This bootloader version seems to be locked and does not react on any input.
cid reg:00010102, cid:1[04010D07][04010D0A]
DDR Calibration DQS reg = 00008988
DDR Calibration MEMCTRL reg = 0E120003
U-Boot 1.1.3 (Nov 28 2020 - 10:44:01)
Board: Ralink APSoC DRAM: 64 MB
relocate_code Pointer at: 83fb8000
flash manufacture id: 20, device id 70 17
Warning: un-recognized chip ID, please update bootloader!
*** Warning - bad CRC, using default environment
============================================
Ralink UBoot Version: 5.0.0.0
--------------------------------------------
ASIC 7628_MP (Port5<->None)
DRAM component: 512 Mbits DDR, width 16
DRAM bus: 16 bit
Total memory: 64 MBytes
Flash component: SPI Flash
Date:Nov 28 2020 Time:10:44:01
============================================
icache: sets:512, ways:4, linesz:32 ,total:65536
dcache: sets:256, ways:4, linesz:32 ,total:32768
##### The CPU freq = 580 MHZ ####
estimate memory size =64 Mbytes
RESET MT7628 PHY!!!!!!
Please choose the operation:
1: Load system code to SDRAM via TFTP.
2: Load system code then write to Flash via TFTP.
3: Boot system code via Flash (default).
4: Entr boot command line interface.
7: Load Boot Loader code then write to Flash via Serial.
9: Load Boot Loader code then write to Flash via TFTP.
default: 3
You choosed 3
0
3: System Boot system code via Flash.
tplink_turn_off_led
## Booting image at bc020000 ...
text base: 80000000
entry point: 8000c150
Uncompressing Kernel Image ... OK
No initrd
## Transferring control to Linux (at address 8000c150) ...
## Giving linux memsize in MB, 64
Starting kernel ...
COPY HERE THE BOOTLOG ONCE OPENWRT IS INSTALLED AND RUNNING
Space for additional notes, links to forum threads or other resources.
Add tags below, then remove this fixme.